Copyright (c) Hyperion Entertainment and contributors.

Difference between revisions of "AmigaOS Manual: Workbench ARexx Port"

From AmigaOS Documentation Wiki
Jump to navigation Jump to search
Line 1,085: Line 1,085:
   
 
UNZOOMWINDOW root
 
UNZOOMWINDOW root
  +
</syntaxhighlight>
  +
  +
= VIEW command =
  +
  +
; Purpose:
  +
: This command will change the position of the viewable display area of a window.
  +
  +
; Format:
  +
: VIEW [WINDOW] <ROOT|ACTIVE|Drawer name> [PAGE|PIXEL] [UP|DOWN|LEFT|RIGHT]
  +
  +
; Template:
  +
: VIEW WINDOW,PAGE/S,PIXEL/S,UP/S,DOWN/S,LEFT/S,RIGHT/S
  +
  +
; Parameters:
  +
: WINDOW
  +
:: Either "ROOT" to change the Workbench root window view (where volume icons and AppIcons live), "ACTIVE" to change the currently active Workbench window view or the fully qualified name of a drawer window to change. Note that the drawer window must already be open.
  +
:: If no WINDOW parameter is specified, this command will try to operate on the currently active Workbench window.
  +
  +
: UP
  +
:: Move the view up by about 1/8 of the window height. If PAGE is specified, moves the view up by a whole page. If PIXEL is specified, moves the view up by a single pixel.
  +
  +
: DOWN
  +
:: Move the view down by about 1/8 of the window height. If PAGE is specified, moves the view down by a whole page. If PIXEL is specified, moves the view down by a single pixel.
  +
  +
: LEFT
  +
:: Move the view left by about 1/8 of the window height. If PAGE is specified, moves the view left by a whole page. If PIXEL is specified, moves the view left by a single pixel.
  +
  +
: RIGHT
  +
:: Move the view right by about 1/8 of the window height. If PAGE is specified, moves the view right by a whole page. If PIXEL is specified, moves the view right by a single pixel.
  +
  +
; Errors:
  +
: 10 - If the named window view cannot be changed; this can also happen if you specified "ACTIVE" as the window name and none of the Workbench windows is currently active. The error code will be placed in the WORKBENCH.LASTERROR variable.
  +
  +
; Result:
  +
: -
  +
  +
; Notes:
  +
: If you choose to have a window view changed that is neither the root nor the active window you must make sure that the window name is given as a fully qualified path name. For example "Work:" is a fully qualified name, and so is "SYS:Utilities". "Devs/Printers" would not be a fully qualified name. A fully qualified name always contains the name of an assignment, a volume or a device.
  +
  +
: To find out about a window`s current view position, use the GETATTR command and query the window`s WINDOW.VIEW.LEFT and WINDOW.VIEW.TOP attributes.
  +
  +
; Example:
  +
: <syntaxhighlight>
  +
/* Change the root window view; move it up by a whole page. */
  +
ADDRESS workbench
  +
  +
VIEW root PAGE UP
  +
</syntaxhighlight>
  +
  +
= WINDOW command =
  +
  +
; Purpose:
  +
: This command will change, open, close or snapshot windows.
  +
  +
; Format:
  +
: WINDOW [WINDOWS] <Window name> .. <Window name> [OPEN|CLOSE] [SNAPSHOT] [ACTIVATE] [MIN|MAX] [FRONT|BACK] [CYCLE PREVIOUS|NEXT]
  +
  +
; Template:
  +
: WINDOW WINDOWS/M/A,OPEN/S,CLOSE/S,SNAPSHOT/S,ACTIVATE/S,MIN/S,MAX/S, FRONT/S,BACK/S,CYCLE/K
  +
  +
; Parameters:
  +
: WINDOWS
  +
:: Names of the windows to operate on. This can be "ROOT" to for the Workbench root window (where volume icons and AppIcons live), "ACTIVE" for the currently active Workbench window or the fully qualified name of a drawer window.
  +
  +
: OPEN
  +
:: Attempt to open the specified windows.
  +
  +
: CLOSE
  +
:: Close the specified windows. Note that if a window is closed no further operations (such as SNAPSHOT, ACTIVATE, etc.) can be performed on it.
  +
  +
: SNAPSHOT
  +
:: Snapshot the sizes and positions of the specified windows.
  +
  +
: ACTIVATE
  +
:: Activate the specified windows. With multiple windows to activate, only one window will wind up as the active one. Commonly, this will be the last window in the list.
  +
  +
: MIN
  +
:: Resize the windows to their minimum dimensions.
  +
  +
: MAX
  +
:: Resize the windows to their maximum dimensions.
  +
  +
: FRONT
  +
:: Move the windows into the foreground.
  +
  +
: BACK
  +
:: Move the windows into the background.
  +
  +
: CYCLE
  +
:: This command operates on the currently active drawer window. You can specify either "PREVIOUS", to activate the previous drawer window in the list, or "NEXT", to activate the next following drawer window in the list.
  +
  +
; Errors:
  +
: 10 - If the named windows cannot be opened or operated on; this can also happen if you specified "ACTIVE" as a window name and none of the Workbench windows is currently active. The error code will be placed in the WORKBENCH.LASTERROR variable.
  +
  +
; Result:
  +
: -
  +
  +
; Notes:
  +
: If you choose to have a window operated on that is neither the root nor the active window you must make sure that the window name is given as a fully qualified path name. For example "Work:" is a fully qualified name, and so is "SYS:Utilities". "Devs/Printers" would not be a fully qualified name. A fully qualified name always contains the name of an assignment, a volume or a device.
  +
  +
; Example:
  +
: <syntaxhighlight>
  +
/* Open the "Work:" drawer. */
  +
ADDRESS workbench
  +
  +
WINDOW 'Work:' OPEN
  +
  +
/* Activate the root window. */
  +
WINDOW root ACTIVATE
 
</syntaxhighlight>
 
</syntaxhighlight>

Revision as of 23:47, 23 January 2014

Workbench acts as an ARexx host under the name of "WORKBENCH". It supports a number of commands as will be described below. Note that for the ARexx interface to work, rexxsyslib.library must be installed (this library is part of a regular Workbench installation) and the RexxMast program must have been started.

ACTIVATEWINDOW command

Purpose
This command will attempt to make a window the active one.
Format
ACTIVATEWINDOW [WINDOW] <ROOT|Drawer name>
Template
ACTIVATEWINDOW WINDOW
Parameters
WINDOW
Either "ROOT" to activate the Workbench root window (where volume icons and AppIcons live) or the fully qualified name of a drawer window to activate. Note that the drawer window must already be open.
If no WINDOW parameter is specified, this command will try to operate on the currently active Workbench window.
Errors
10 - If the named window cannot be activated. The error code will be placed in the WORKBENCH.LASTERROR variable.
Result
-
Notes
If you choose to have a window activated that is not the root window you must make sure that the window name is given as a fully qualified path name. For example Work:" is a fully qualified name, and so is SYS:Utilities". Devs/Printers" would not be a fully qualified name. A fully qualified name always contains the name of an assignment, a volume or a device.
Example
/* Activate the root window. */ ADDRESS workbench

ACTIVATEWINDOW root   /* Activate the "Work:" partition's window. */ ACTIVATEWINDOW 'Work:'

CHANGEWINDOW command

Purpose
This command will attempt to change the size and the position of a window.
Format
CHANGEWINDOW [WINDOW] <ROOT|ACTIVE|Drawer name> [[LEFTEDGE] <new left edge position>][[TOPEDGE] <new top edge position>][[WIDTH] <new window width>][[HEIGHT] <new window height>]
Template
CHANGEWINDOW WINDOW,LEFTEDGE/N,TOPEDGE/N,WIDTH/N,HEIGHT/N
Parameter
WINDOW
Either "ROOT" to resize/move the Workbench root window (where volume icons and AppIcons live), "ACTIVE" to change the currently active Workbench window or the fully qualified name of a drawer window to change. Note that the drawer window must already be open.
If no WINDOW parameter is specified, this command will try to operate on the currently active Workbench window.
LEFTEDGE
New left edge window position.
TOPEDGE
New top edge window position.
WIDTH
New window width.
HEIGHT
New window height.
Errors
10 - If the named window cannot be changed; this can also happen if you specified ACTIVE" as the window name and none of the Workbench windows is currently active. The error code will be placed in the WORBENCH.LASTERROR variable.
Result
-
Notes
If you choose to have a window changed that is neither the root nor the active window you must make sure that the window name is given as a fully qualified path name. For example "Work:" is a fully qualified name, and so is "SYS:Utilities". "Devs/Printers" would not be a fully qualified name. A fully qualified name always contains the name of an assignment, a volume or a device.
Example
/* Change the root window; move it to position 10,30. * and change its size to 200100 pixels. */

ADDRESS workbench CHANGEWINDOW root LEFTEDGE 10 TOPEDGE 30 WIDTH 200 HEIGHT 100   /* Change the currently active window. */ CHANGEWINDOW active 20 40 200 100

DELETE command

Purpose
This command is for deleting files and drawers (and their contents).
Format
DELETE [NAME] <File or drawer name> [ALL]
Template
DELETE NAME/A,ALL/S
Parameters
NAME
Name of the file or drawer or volume to delete.
ALL
If the object in question is a drawer, attempt to delete the contents of the drawer as well as the drawer itself. If this option is not specified, the DELETE command will only attempt to delete the drawer itself, which may fail if the drawer is not yet empty.
Errors
10 - If the named file, drawer or volume could not be found or could not be deleted.
Result
-
Notes
The file name given must be an absolute path, such as in "RAM:Empty". A relative path, such as "/fred/barney" will not work.
Example
/* Delete the contents of the drawer RAM:Empty". */

  ADDRESS workbench DELETE 'RAM:Empty' ALL

FAULT command

Purpose
This command will return a human readable explanation corresponding to an error code.
Format
FAULT [CODE] <Error code>
Template
FAULT CODE/A/N
Parameters
CODE
Error code to return a human readable explanation for.
Errors
-
Result
-
Example
/* Query the error message corresponding to error code #205. */

ADDRESS workbench OPTIONS RESULTS FAULT 205 SAY result

GETATTR command

Purpose
This command will retrieve information from the Workbench database, such the names of the drawers currently open and the icons currently selected.
Format
GETATTR [OBJECT] <Object name> [NAME <Item name>][STEM <Name of stem variable>] [VAR <Variable name>]
Template
GETATTR OBJECT/A,NAME/K,STEM/K,VAR/K
Parameters
OBJECT
Name of the database entry to retrieve. For a list of valid entries see below.
NAME
For some datatabase entries further information is required to identify the data to retrieve. This is when you will need to provide a name.
STEM
If you request more than one database entry you will need to provide a variable to store the information in. For an example of its use, see below.
VAR
If you want the queried information to be stored in a specific variable (other than the RESULT variable), this is where you provide its name.
Attributes
You can obtain information on the following attributes:
APPLICATION.VERSION
Version number of workbench.library".
APPLICATION.SCREEN
Name of the public screen Workbench uses.
APPLICATION.AREXX
Name of the Workbench ARexx port.
APPLICATION.LASTERROR
Number of the last error caused by the ARexx interface.
APPLICATION.ICONBORDER
Sizes of the icon borders, returned as four numbers separated by blank spaces, e.g. "4 3 4 3". The four numbers represent the left border width, the top border height, the right border width and the bottom border height (in exactly that order).
APPLICATION.FONT.SCREEN.NAME
Name of the Workbench screen font.
APPLICATION.FONT.SCREEN.WIDTH APPLICATION.FONT.SCREEN.HEIGHT
Size of a single character of the Workbench screen font. Please note that since the font in question may be proportional spaced the width information may be of little value. To measure the accurate pixel width of a text in reference to the font, use the .SIZE attribute.
APPLICATION.FONT.SCREEN.SIZE
Size of a text, measured in pixels, in reference to the screen font. The text to measure must be provided with the NAME parameter of the GETATTR command.
APPLICATION.FONT.ICON.NAME
Name of the Workbench icon font.
APPLICATION.FONT.ICON.WIDTH APPLICATION.FONT.ICON.HEIGHT
Size of a single character of the Workbench icon font. Please note that since the font in question may be proportional spaced the width information may be of little value. To measure the accurate pixel width of a text in reference to the font, use the .SIZE attribute.
APPLICATION.FONT.ICON.SIZE
Size of a text, measured in pixels, in reference to the icon font. The text to measure must be provided with the NAME parameter of the GETATTR command.
APPLICATION.FONT.SYSTEM.NAME
Name of the system font.
APPLICATION.FONT.SYSTEM.WIDTH
APPLICATION.FONT.SYSTEM.HEIGHT
Size of a single character of the system font.
APPLICATION.FONT.SYSTEM.SIZE
Size of a text, measured in pixels, in reference to the system font. The text to measure must be provided with the NAME parameter of the GETATTR command.
WINDOWS.COUNT
Number of the drawer windows currently open. This can be 0.
WINDOWS.0 .. WINDOWS.N
Names of the windows currently open.
WINDOWS.ACTIVE
Name of the currently active Workbench window; this will be " if none of Workbench`s windows is currently active.
KEYCOMMANDS.COUNT
Number of keyboard commands assigned. This can be 0.
KEYCOMMANDS.0 .. KEYCOMMANDS.N
Information on all the keyboard commands assigned.
KEYCOMMANDS.<n>.NAME
Name of the keyboard command.
KEYCOMMANDS.<n>.KEY
The key combination assigned to this keyboard command.
KEYCOMMANDS.<n>.COMMAND
The ARexx command assigned to this key combination.
MENUCOMMANDS.COUNT
Number of menu commands assigned (through the MENU ADD .." command). This can be 0.
MENUCOMMANDS.0 .. MENUCOMMANDS.N
Information on all the menu commands assigned.
MENUCOMMANDS.<n>.NAME
Name of this menu item.
MENUCOMMANDS.<n>.TITLE
Title of this menu item.
MENUCOMMANDS.<n>.SHORTCUT
The keyboard shortcut assigned to this menu item.
MENUCOMMANDS.<n>.COMMAND
The ARexx command assigned to this menu item.
The following attributes require the name of the window to obtain information.
WINDOW.LEFT
Left edge of the window.
WINDOW.TOP
Top edge of the window.
WINDOW.WIDTH
Width of the window.
WINDOW.HEIGHT
Height of the window.
WINDOW.MIN.WIDTH
Minimum width of the window.
WINDOW.MIN.HEIGHT
Minimum height of the window.
WINDOW.MAX.WIDTH
Maximum width of the window.
WINDOW.MAX.HEIGHT
Maximum height of the window.
WINDOW.VIEW.LEFT
Horizontal offset of the drawer contents; this value corresponds to the horizontal window scroller position.
WINDOW.VIEW.TOP
Vertical offset of the drawer contents; this value corresponds to the vertical window scroller position.
WINDOW.SCREEN.NAME
Name of the public screen the window was opened on.
WINDOW.SCREEN.WIDTH WINDOW.SCREEN.HEIGHT
Size of the public screen the window was opened on.
WINDOW.ICONS.ALL.COUNT
Number of the icons displayed in the window. This can be 0.
WINDOW.ICONS.ALL.0 .. WINDOW.ICONS.ALL.N
Information on all the icons displayed in the window:
WINDOW.ICONS.ALL.<n>.NAME
Name of the icon in question.
WINDOW.ICONS.ALL.<n>.LEFT WINDOW.ICONS.ALL.<n>.TOP
Position of the icon in question.
WINDOW.ICONS.ALL.<n>.WIDTH WINDOW.ICONS.ALL.<n>.HEIGHT
Size of the icon in question.
WINDOW.ICONS.ALL.<n>.TYPE
Type of the icon; one of DISK, DRAWER, TOOL, PROJECT,GARBAGE, DEVICE, KICK or APPICON.
WINDOW.ICONS.ALL.<n>.STATUS
Whether the icon is selected and (if the icon is a drawer-like object, such as a disk, drawer or trashcan icon) whether the corresponding drawer is currently open or closed. This attribute is returned in the form of a string, such as "SELECTED OPEN" which means that the icon is selected and the corresponding drawer is currently open. The other options include "UNSELECTED" and "CLOSED".
WINDOW.ICONS.SELECTED.COUNT
Number of the selected icons displayed in the window. This can be 0.
WINDOW.ICONS.SELECTED.0 .. WINDOW.ICONS.SELECTED.N
Information on all selected the icons in the window:
WINDOW.ICONS.SELECTED.<n>.NAME
Name of the icon in question.
WINDOW.ICONS.SELECTED.<n>.LEFT WINDOW.ICONS.SELECTED.<n>.TOP
Position of the icon in question.
WINDOW.ICONS.SELECTED.<n>.WIDTH WINDOW.ICONS.SELECTED.<n>.HEIGHT
Size of the icon in question.
WINDOW.ICONS.SELECTED.<n>.TYPE
Type of the icon; one of DISK, DRAWER, TOOL, PROJECT,GARBAGE, DEVICE, KICK or APPICON.
WINDOW.ICONS.SELECTED.<n>.STATUS
Whether the icon is selected and (if the icon is a drawer-like object, such as a disk, drawer or trashcan icon) whether the corresponding drawer is currently open or closed. This attribute is returned in the form of a string, such as "SELECTED OPEN" which means that the icon is selected and the corresponding drawer is currently open. The other options include "UNSELECTED" and CLOSED". Of course, for the WINDOW.ICONS.SELECTED stem the icon status will always be reported as "SELECTED".
WINDOW.ICONS.UNSELECTED.COUNT
Number of the unselected icons displayed in the window. This can be 0.
WINDOW.ICONS.UNSELECTED.0 .. WINDOW.ICONS.UNSELECTED.N
Information on all selected the icons in the window:
WINDOW.ICONS.UNSELECTED.<n>.NAME
Name of the icon in question.
WINDOW.ICONS.UNSELECTED.<n>.LEFT WINDOW.ICONS.UNSELECTED.<n>.TOP
Position of the icon in question.
WINDOW.ICONS.UNSELECTED.<n>.WIDTH WINDOW.ICONS.UNSELECTED.<n>.HEIGHT
Size of the icon in question.
WINDOW.ICONS.UNSELECTED.<n>.TYPE
Type of the icon; one of DISK, DRAWER, TOOL, PROJECT, GARBAGE, DEVICE, KICK or APPICON.
WINDOW.ICONS.UNSELECTED.<n>.STATUS
Whether the icon is selected and (if the icon is a drawer-like object, such as a disk, drawer or trashcan icon) whether the corresponding drawer is currently open or closed. This attribute is returned in the form of a string, such as "UNSELECTED OPEN" which means that the icon is selected and the corresponding drawer is currently open. The other options include "SELECTED" and CLOSED". Of course, for the WINDOW.ICONS.UNSELECTED stem the icon status will always be reported as "UNSELECTED".
Errors
10 - If the requester information could not be retrieved, you requested more than one database entry and did not provide a stem variable or if you provided a stem variable but did not request more than one database entry. The error code will be placed in the WORKBENCH.LASTERROR variable.
Result
RESULT - The information retrieved from the database.
Example
/* Query the Workbench version. */

ADDRESS workbench OPTIONS RESULTS   GETATTR application.version SAY result   /* Query the Workbench version and store it in the * variable `version_number`. */ GETATTR application.version VAR version_number SAY version_number   /* Query the names of all currently open windows, * then print them. */ GETATTR windows STEM window_list   DO i = 0 TO window_list.count-1 SAY window_list.i; END;   /* Query name, position and size of the first icon * shown in the root window. */ GETATTR window.icons.all.0 NAME root STEM root   SAY root.name SAY root.left SAY root.top SAY root.width SAY root.height SAY root.type   /* Query the width and height of the root window. */ GETATTR window.width NAME root SAY result   GETATTR window.height NAME root SAY result   /* Query the length of a text (in pixels) with reference * to the icon font. */ GETATTR application.font.icon.size NAME 'Text to measure' SAY result

HELP command

Purpose
This command can be used to open the online help and to obtain information on the supported menus, commands and command parameters.
Format
HELP [COMMAND <Command name>] [MENUS] [PROMPT]
Template
HELP COMMAND/K,MENUS/S,PROMPT/S
Parameters
COMMAND
Name of the command whose command template should be retrieved.
MENUS
Specify this parameter to retrieve a list of menu items currently available.
PROMPT
Specify this parameter to invoke the online help system.
If no parameter is provided, a list of supported commands will be returned.
Errors
10 - If the named command is not supported by the ARexx interface. The error code will be placed in the WORKBENCH.LASTERROR variable.
Result
RESULT
The command template, list of menu items or commands, as specified in the command parameters.
Example
/* Retrieve the list of supported commands. */

ADDRESS workbench OPTIONS results   HELP SAY result   /* Retrieve the command template of the `GETATTR` command. */ HELP COMMAND getattr SAY result   /* Retrieve the list of available menu items. */ HELP MENUS SAY result

ICON command

Purpose
This command is for manipulating the icons displayed in a window.
Format
ICON [WINDOW] <Window name> <Icon name> .. <Icon name> [OPEN] [MAKEVISIBLE] [SELECT] [UNSELECT] [UP <Pixels>] [DOWN <Pixels>] [LEFT <Pixels>] [RIGHT <Pixels>] [X <Horizontal position>] [Y <Vertical position>] [ACTIVATE UP|DOWN|LEFT|RIGHT] [CYCLE PREVIOUS|NEXT] [MOVE IN|OUT]
Template
ICON WINDOW,NAMES/M,OPEN/S,MAKEVISIBLE/S,SELECT/S,UNSELECT/S, UP/N,DOWN/N,LEFT/N,RIGHT/N,X/N,Y/N,ACTIVATE/K,CYCLE/K, MOVE/K
Parameters
WINDOW
Name of the window whose icons should be manipulated. This can be "ROOT" to work on the Workbench root window (where volume icons and AppIcons live), "ACTIVE" to work on the currently active Workbench window or the fully qualified name of a drawer window. Note that the drawer window must already be open.
If no WINDOW parameter is specified, this command will try to operate on the currently active Workbench window.
NAMES
Names of the icons to manipulate.
OPEN
Specifies that the named icons should be opened.
MAKEVISIBLE
Specifies that the named icons should be made visible. This generally works well for the first icon in a list but does not always work for a whole list.
SELECT
Select the named icons.
UNSELECT
Unselect the named icons.
UP, DOWN, LEFT, RIGHT
Move the named icons by the specified number of pixels.
X, Y
Move the named icons to the specified position.
ACTIVATE
This command is for activating the icon closest to the currently selected icon in the window. "Activating" in this context means selecting an icon, whilst at the same time unselecting all others. Thus, the "active" icon is the only selected icon in the window.
You can indicate which direction the next icon to be activated should be searched for, relative to the currently active icon. "UP" searches upwards, "DOWN" searches downwards, "LEFT" searches to the left and "RIGHT" searches to the right.
CYCLE
This command is for cycling through all icons in a window, making each one the active one in turn (for a description of what "active" means in this context, see the "ACTIVATE" description above). You must indicate in which direction you want to cycle through the icons: you can either specify "PREVIOUS" or "NEXT".
MOVE
This command is not for moving icons but for moving through a file system hierarchy. Thus, moving "in" will open a drawer and moving "out" will open the drawer's parent directory. The "IN" parameter will cause the drawer represented by the active icon to be opened. Please note that an icon must be selected and it must be a drawer. The "OUT" parameter will open the drawer's parent directory, and it also requires that in the drawer there is an icon selected. This may sound strange, but this feature is not meant as a replacement for the "Open Parent" menu item.
Errors
10 - If the named window cannot be found, none of the Workbench windows are currently active and the command was set to work on the currently active Workbench window. The error code will be placed in the WORKBENCH.LASTERROR variable.
Result
-
Example
/* Select the icons of the "Workbench" and "Work" volumes displayed in the root window. */

ADDRESS workbench   ICON WINDOW root NAMES Workbench Work SELECT   /* Open the "Workbench" volume icon displayed in the root window. */ ICON WINDOW root NAMES Workbench OPEN

INFO command

Purpose
This command is for opening the Workbench icon information requester.
Format
INFO [NAME] <File, drawer or volume name>
Template
INFO NAME/A
Parameters 
NAME
Name of the file, drawer or volume to open the information window for.
Errors
10 - If the named file, drawer or volume could not be found. The error code will be placed in the WORKBENCH.LASTERROR variable.
Result
-
Example
/* Open the information window for SYS:". */

ADDRESS workbench   INFO NAME 'SYS:'

KEYBOARD command

Purpose
This command can be used to bind ARexx commands to key combinations.
Format
KEYBOARD [NAME] <Name of key combination> ADD|REMOVE [KEY <Key combination>] [CMD <ARexx command>]
Template
KEYBOARD NAME/A,ADD/S,REMOVE/S,KEY,CMD/F
Parameters
NAME
Name of the key combination to add or remove. Each key combination must have a name with which it is associated. The name must be unique.
ADD
This tells the KEYBOARD command to add a new keyboard combination. You will also need to specify the KEY and CMD parameters.
REMOVE
This tells the KEYBOARD command to remove an existing keyboard combination.
KEY
The keyboard combination to add; this must be in the same format as used by the Commodities programs.
CMD
This is the ARexx command to bind to the keyboard combination. The command can either be the name of an ARexx script to execute or a short ARexx program in a single line.
Errors
10 - The command will fail if you tried to add a duplicate of an existing key combination or if the key combination to remove does not exist. The error code will be placed in the WORKBENCH.LASTERROR variable.
Result
-
Example
/* Bind an ARexx script to the [Control]+A key combination.

* When pressed, this will cause the ARexx script by the name * test.wb" to be executed. ARexx will search for that program * in the REXX:" directory. If no "test.wb" file can be found, ARexx will attempt to execute a script * by the name of test.rexx". */   ADDRESS workbench   KEYBOARD ADD NAME test1 KEY ,"ctrl a", CMD ,'test'   /* Bind an ARexx script to the [Alt]+[F1] key combination. * When pressed, this will cause a short inline program to be * executed. */ KEYBOARD ADD NAME test2 KEY ,"alt f1", CMD "say 42"   /* Bind an ARexx script to the [Shift]+[Help] key combination. * When pressed, this will cause the "Workbench About" menu item * to be invoked. */ KEYBOARD ADD NAME test3 KEY ,"shift help", CMD "MENU INVOKE WORKBENCH.ABOUT"   /* Remove the first key combination we added above. */ KEYBOARD REMOVE NAME test1

LOCKGUI command

Purpose
This command will block access to all Workbench drawer windows.
Format
LOCKGUI
Template
LOCKGUI
Parameters
-
Errors
-
Result
-
Notes
It takes as many UNLOCKGUI commands as there were LOCKGUI commands to make the Workbench drawer windows usable again. In other words, the LOCKGUI command nests".
Example
/* Block access to all Workbench drawer windows. */

ADDRESS workbench   LOCKGUI

MENU command

Purpose
This command is for invoking items of the Workbench menu, as if the user had selected them with the mouse and for adding/removing user menus.
Format
MENU [WINDOW <Window name>] [INVOKE] <Menu name> [NAME <Menu name>] [TITLE <Menu title>] [SHORTCUT <Menu shortcut>] [ADD|REMOVE] [CMD <ARexx command>]
Template
MENU WINDOW/K,INVOKE,NAME/K,TITLE/K,SHORTCUT/K,ADD/S,REMOVE/S,CMD/K/F
Parameters
The following set of parameters can be used solely for invoking menu items.
WINDOW
Name of the window whose menu should be invoked. This can be "ROOT" to work on the Workbench root window (where volume icons and AppIcons live), "ACTIVE" to work on the currently active Workbench window or the fully qualified name of a drawer window. Note that the drawer window must already be open.
If no WINDOW parameter is specified, this command will try to operate on the currently active Workbench window.
INVOKE
Name of the menu to invoke. See below for a list of available menu items.
The following set of parameters are for adding and removing menu items.
NAME
Name of the menu item to add or remove. Each menu item must have a name with which it is associated. The name must be unique and has nothing to do with the title of the item, as shown in the Tools" menu.
TITLE
This is the text that will be used as the menu item title, as it will appear in the Tools" menu. This parameter is required if you ADD a new menu item.
SHORTCUT
When adding a new menu item, this will be the menu shortcut associated with the item. Please note that the shortcut cannot be longer than a single character and that it will be ignored if there already is an item in any of the menus which uses this shortcut. This parameter is optional.
ADD
This tells the MENU command to add a new item to the "Tools" menu. When adding a menu item you will also need to specify the NAME, TITLE and CMD parameters.
REMOVE
This tells the MENU command to remove a menu item previously added via the ARexx interface. When removing a menu item you will also need to specify the NAME parameter.
CMD
This is the ARexx command to bind to the new menu item. The command can either be the name of an ARexx script to execute or a short ARexx program in a single line.
Menu items:
WORKBENCH.BACKDROP
Toggles the Workbench "Backdrop" window switch.
WORKBENCH.EXECUTE
Invokes the Workbench "Execute Command" requester. The user will be prompted to enter the command to be executed.
WORKBENCH.REDRAWALL
Invokes the Workbench "Redraw All" function.
WORKBENCH.UPDATEALL
Invokes the Workbench "Update All" function.
WORKBENCH.LASTMESSAGE
Redisplays the last Workbench error message.
WORKBENCH.ABOUT
Displays the "Workbench About..." requester.
WORKBENCH.QUIT
Attempts to close Workbench; this may bring up a requester the user will have to answer.
WINDOW.NEWDRAWER
Prompts the user to enter the name of a new drawer to be created.
WINDOW.OPENPARENT
If possible, this will open the parent directory of the drawer the command operates on.
WINDOW.CLOSE
If possible, this will close the drawer the command operates on.
WINDOW.UPDATE
This will update the drawer the command operates on, i.e. the contents will be reread.
WINDOW.SELECTCONTENTS
This will select the contents of the drawer the command operates on.
WINDOW.CLEARSELECTION
This unselects all icons selected in the drawer the command operates on.
WINDOW.CLEANUPBY.COLUMN
This will sort the contents of the drawer and place the icons in columns.
WINDOW.CLEANUPBY.NAME
This will sort the contents of the drawer by name and place the icons in rows.
WINDOW.CLEANUPBY.DATE
This will sort the contents of the drawer by date and place the icons in rows.
WINDOW.CLEANUPBY.SIZE
This will sort the contents of the drawer by size and place the icons in rows.
WINDOW.CLEANUPBY.TYPE
This will sort the contents of the drawer by type and place the icons in rows.
WINDOW.RESIZETOFIT
This will resize the drawer window, trying to make it just as large as to allow all its icons to fit.
WINDOW.SNAPSHOT.WINDOW
This will snapshot the drawer window, but none of its contents.
WINDOW.SNAPSHOT.ALL
This will snapshot the drawer window and its contents.
WINDOW.SHOW.ONLYICONS
This will change the display mode of the drawer to show only files and drawers which have icons attached.
WINDOW.SHOW.ALLFILES
This will change the display mode of the drawer to show all files and drawers, regardless of whether they have icons attached or not.
WINDOW.VIEWBY.ICON
This will change the display mode of the drawer to show its contents as icons.
WINDOW.VIEWBY.NAME
This will change the display mode of the drawer to show its contents in textual format, sorted by name.
WINDOW.VIEWBY.DATE
This will change the display mode of the drawer to show its contents in textual format, sorted by date.
WINDOW.VIEWBY.SIZE
This will change the display mode of the drawer to show its contents in textual format, sorted by size.
WINDOW.VIEWBY.TYPE
This will change the display mode of the drawer to show its contents in textual format, sorted by type.
ICONS.OPEN
This will open the currently selected icons. Workbench may bring up a requester in case project icons are found which lack a default tool.
ICONS.COPY
This will duplicate the currently selected icons.
ICONS.RENAME
This will prompt the user to choose a new name for each currently selected icon.
ICONS.INFORMATION
This will open the information window for every currently selected icon.
ICONS.SNAPSHOT
This will lock the position of every currently selected icon.
ICONS.UNSNAPSHOT
This will unlock the position of every currently selected icon.
ICONS.LEAVEOUT
This will permanently put all currently selected icons on the Workbench root window.
ICONS.PUTAWAY
This will move all currently selected icons out of the root window and put them back into the drawers they belong.
ICONS.DELETE
This will cause all currently selected files to be deleted, provided the user confirms this action first.
ICONS.FORMATDISK
This will invoke the "Format" command on every currently selected disk icon. This will not format the disks immediately. The user will have to confirm this action first.
ICONS.EMPTYTRASH
With a trashcan icon selected, this will empty it.
TOOLS.RESETWB
This will close and reopen all Workbench windows.
The HELP command will provide a complete list of menu items that can be invoked. Depending on the state of each menu item (e.g. the "Open" menu item will be disabled if no icon is currently selected) the MENU command can silently fail to invoke the item you had in mind.
Errors
10 - If the named window cannot be found, none of the Workbench windows are currently active and the command was set to work on the currently active Workbench window. The command can also fail if you tried to add a duplicate of an existing menu item or if the menu item to remove does not exist. The error code will be placed in the WORKBENCH.LASTERROR variable.
Result
-
Example
/* Invoke the "About" menu. */

ADDRESS workbench   MENU WINDOW root INVOKE WORKBENCH.ABOUT   /* Add an item to the Tools" menu; selecting it * will cause the ARexx script by the name "test.wb" * to be executed. ARexx will search for that program * in the "REXX:" directory. If no "test.wb" file can * be found, ARexx will attempt to execute a script * by the name of "test.rexx". */ MENU ADD NAME test1 TITLE ,"Execute a script", SHORTCUT ,'!' CMD ,'test'   /* Add an item to the "Tools" menu; selecting it * will cause a short inline program to be executed. */ MENU ADD NAME test2 TITLE ,"Short inline program", CMD "say 42"   /* Add an item to the "Tools" menu; selecting it * will cause the Workbench "About" menu item to be invoked. */ MENU ADD NAME test3 TITLE ,"About...", CMD "MENU INVOKE WORKBENCH.ABOUT"   /* Remove the first menu item we added above. */ MENU REMOVE NAME test1

MOVEWINDOW command

Purpose
This command will attempt to change the position of a window.
Format
MOVEWINDOW [WINDOW] <ROOT|ACTIVE|Drawer name> [[LEFTEDGE] <new left edge position>] [[TOPEDGE] <new top edge position>]
Template
MOVEWINDOW WINDOW,LEFTEDGE/N,TOPEDGE/N
Parameters
WINDOW
Either "ROOT" to move the Workbench root window (where volume icons and AppIcons live), "ACTIVE" to move the currently active Workbench window or the fully qualified name of a drawer window to change. Note that the drawer window must already be open.
If no WINDOW parameter is specified, this command will try to operate on the currently active Workbench window.
LEFTEDGE
New left edge window position.
TOPEDGE
New top edge window position.
Errors
10 - If the named window cannot be moved; this can also happen if you specified "ACTIVE" as the window name and none of the Workbench windows is currently active. The error code will be placed in the WORKBENCH.LASTERROR variable.
Result
-
Notes
If you choose to have a window changed that is neither the root nor the active window you must make sure that the window name is given as a fully qualified path name. For example "Work:" is a fully qualified name, and so is "SYS:Utilities". "Devs/Printers" would not be a fully qualified name. A fully qualified name always contains the name of an assignment, a volume or a device.
Example
/* Move the root window to position 10,30. */

ADDRESS workbench   MOVEWINDOW root LEFTEDGE 10 TOPEDGE 30   /* Move the currently active window. */ MOVEWINDOW active 20 40

NEWDRAWER command

Purpose
This command is for creating new drawers.
Format
NEWDRAWER [NAME] <Name of drawer to create>
Template
NEWDRAWER NAME/A
Parameters
NAME
Name of the drawer to be created.
Errors
10 - If the named drawer could not be created.
Result
-
Notes
The drawer name given must be an absolute path, such as in "RAM:Empty". A relative path, such as "/fred/barney" will not work.
Example 
/* Create a drawer by the name of "Empty" in the RAM disk. */

ADDRESS workbench   NEWDRAWER 'RAM:Empty'

RENAME command

Purpose
This command is for renaming files, drawers and volumes.
Format
RENAME [OLDNAME] <Name of file/drawer/volume to rename> [NEWNAME] <New name of the file/drawer/volume>
Template
RENAME OLDNAME/A,NEWNAME/A
Parameters
OLDNAME
Name of the file/drawer/volume to be renamed. This must be an absolute path, such as in "RAM:Empty". A relative path, such as "/fred/barney", will not work.
NEWNAME
The new name to assign to the file/drawer/volume. This must not be an absolute or relative path. For example, "wilma" is valid new name, "/wilma" or "wilma:" would be invalid names.
Errors
10 - If the object cannot be renamed.
Result
-
Notes
The RENAME command does not work like for example the AmigaDOS "Rename" command. For example, RENAME 'ram:empty' ,'newname' will rename the file 'RAM:empty' to 'RAM:newname'.
Example
/* Rename a drawer by the name of "Old" in the RAM disk to "New". */

ADDRESS workbench   RENAME 'RAM:Old' 'New'

RX command

Purpose
This command is for executing ARexx scripts and commands.
Format
RX [CONSOLE] [ASYNC] [CMD] <Command to execute>
Template
RX CONSOLE/S,ASYNC/S,CMD/A/F
Parameters
CONSOLE
This switch indicates that a console (for default I/O) is needed.
ASYNC
This switch indicates that the command should be run asynchronously, i.e. the "RX" command will return as soon as ARexx has been instructed to run the command you specified. Otherwise, the "RX" command will wait for the specified ARexx command to complete execution.
COMMAND
This is the name of the ARexx program to execute.
Errors
10 - If the given ARexx program could not be executed.
Result
-
Example
/* Execute an ARexx program by the name of 'test.wb';

* its output should be sent to a console window. */ ADDRESS workbench   RX CONSOLE CMD 'test.wb'

SIZEWINDOW command

Purpose
This command will attempt to change the size of a window.
Format
SIZEWINDOW [WINDOW] <ROOT|ACTIVE|Drawer name> [[WIDTH] <new window width>] [[HEIGHT] <new window height>]
Template
SIZEWINDOW WINDOW,WIDTH/N,HEIGHT/N
Parameters
WINDOW
Either "ROOT" to resize the Workbench root window (where volume icons and AppIcons live), "ACTIVE" to resize the currently active Workbench window or the fully qualified name of a drawer window to change. Note that the drawer window must already be open.
If no WINDOW parameter is specified, this command will try to operate on the currently active Workbench window.
WIDTH
New window width.
HEIGHT
New window height.
Errors
10 - If the named window cannot be resized; this can also happen if you specified "ACTIVE" as the window name and none of the Workbench windows is currently active. The error code will be placed in the WORKBENCH.LASTERROR variable.
Result
-
Notes
If you choose to have a window resized that is neither the root nor the active window you must make sure that the window name is given as a fully qualified path name. For example "Work:" is a fully qualified name, and so is "SYS:Utilities". "Devs/Printers" would not be a fully qualified name. A fully qualified name always contains the name of an assignment, a volume or a device.
Example
/* Change the root window size to 200100 pixels. */

ADDRESS workbench   SIZEWINDOW root 30 WIDTH 200 HEIGHT 100   /* Resize the currently active window. */ SIZEWINDOW active 200 100

UNLOCKGUI command

Purpose
This command will allow access to all Workbench drawer windows locked with the LOCKGUI command.
Format
UNLOCKGUI
Template
UNLOCKGUI
Parameters
-
Errors
-
Result
-
Notes
It takes as many UNLOCKGUI commands as there were LOCKGUI commands to make the Workbench drawer windows usable again. In other words, the LOCKGUI command "nests".
Example
/* Reallow access to all Workbench drawer windows. */

ADDRESS workbench   UNLOCKGUI

UNZOOMWINDOW command

Purpose
This command will attempt return a window to its original position and dimensions.
Format
UNZOOMWINDOW [WINDOW] <ROOT|ACTIVE|Drawer name>
Template
UNZOOMWINDOW WINDOW
Parameters
WINDOW
Name of the window to operate on. "ROOT" will use the Workbench root window (where volume icons and AppIcons live), "ACTIVE" will use the currently active Workbench window. Any other fully qualified path name will use the drawer window corresponding to the path.
If no WINDOW parameter is specified, this command will try to operate on the currently active Workbench window.
Errors
10 - If the named window cannot be found. The error code will be placed in the WORKBENCH.LASTERROR variable.
Result
-
Example
/* Change the root window. */

ADDRESS workbench   UNZOOMWINDOW root

VIEW command

Purpose
This command will change the position of the viewable display area of a window.
Format
VIEW [WINDOW] <ROOT|ACTIVE|Drawer name> [PAGE|PIXEL] [UP|DOWN|LEFT|RIGHT]
Template
VIEW WINDOW,PAGE/S,PIXEL/S,UP/S,DOWN/S,LEFT/S,RIGHT/S
Parameters
WINDOW
Either "ROOT" to change the Workbench root window view (where volume icons and AppIcons live), "ACTIVE" to change the currently active Workbench window view or the fully qualified name of a drawer window to change. Note that the drawer window must already be open.
If no WINDOW parameter is specified, this command will try to operate on the currently active Workbench window.
UP
Move the view up by about 1/8 of the window height. If PAGE is specified, moves the view up by a whole page. If PIXEL is specified, moves the view up by a single pixel.
DOWN
Move the view down by about 1/8 of the window height. If PAGE is specified, moves the view down by a whole page. If PIXEL is specified, moves the view down by a single pixel.
LEFT
Move the view left by about 1/8 of the window height. If PAGE is specified, moves the view left by a whole page. If PIXEL is specified, moves the view left by a single pixel.
RIGHT
Move the view right by about 1/8 of the window height. If PAGE is specified, moves the view right by a whole page. If PIXEL is specified, moves the view right by a single pixel.
Errors
10 - If the named window view cannot be changed; this can also happen if you specified "ACTIVE" as the window name and none of the Workbench windows is currently active. The error code will be placed in the WORKBENCH.LASTERROR variable.
Result
-
Notes
If you choose to have a window view changed that is neither the root nor the active window you must make sure that the window name is given as a fully qualified path name. For example "Work:" is a fully qualified name, and so is "SYS:Utilities". "Devs/Printers" would not be a fully qualified name. A fully qualified name always contains the name of an assignment, a volume or a device.
To find out about a window`s current view position, use the GETATTR command and query the window`s WINDOW.VIEW.LEFT and WINDOW.VIEW.TOP attributes.
Example
/* Change the root window view; move it up by a whole page. */

ADDRESS workbench   VIEW root PAGE UP

WINDOW command

Purpose
This command will change, open, close or snapshot windows.
Format
WINDOW [WINDOWS] <Window name> .. <Window name> [OPEN|CLOSE] [SNAPSHOT] [ACTIVATE] [MIN|MAX] [FRONT|BACK] [CYCLE PREVIOUS|NEXT]
Template
WINDOW WINDOWS/M/A,OPEN/S,CLOSE/S,SNAPSHOT/S,ACTIVATE/S,MIN/S,MAX/S, FRONT/S,BACK/S,CYCLE/K
Parameters
WINDOWS
Names of the windows to operate on. This can be "ROOT" to for the Workbench root window (where volume icons and AppIcons live), "ACTIVE" for the currently active Workbench window or the fully qualified name of a drawer window.
OPEN
Attempt to open the specified windows.
CLOSE
Close the specified windows. Note that if a window is closed no further operations (such as SNAPSHOT, ACTIVATE, etc.) can be performed on it.
SNAPSHOT
Snapshot the sizes and positions of the specified windows.
ACTIVATE
Activate the specified windows. With multiple windows to activate, only one window will wind up as the active one. Commonly, this will be the last window in the list.
MIN
Resize the windows to their minimum dimensions.
MAX
Resize the windows to their maximum dimensions.
FRONT
Move the windows into the foreground.
BACK
Move the windows into the background.
CYCLE
This command operates on the currently active drawer window. You can specify either "PREVIOUS", to activate the previous drawer window in the list, or "NEXT", to activate the next following drawer window in the list.
Errors
10 - If the named windows cannot be opened or operated on; this can also happen if you specified "ACTIVE" as a window name and none of the Workbench windows is currently active. The error code will be placed in the WORKBENCH.LASTERROR variable.
Result
-
Notes
If you choose to have a window operated on that is neither the root nor the active window you must make sure that the window name is given as a fully qualified path name. For example "Work:" is a fully qualified name, and so is "SYS:Utilities". "Devs/Printers" would not be a fully qualified name. A fully qualified name always contains the name of an assignment, a volume or a device.
Example
/* Open the "Work:" drawer. */

ADDRESS workbench   WINDOW 'Work:' OPEN   /* Activate the root window. */ WINDOW root ACTIVATE